Insertion Devices by Sector

Insertion Devices by Sector
Location* Device Period (cm) N1 Gap2 (mm) Keff E13 (keV) Pdens3,4 (kW/mrad2) Ptot3,4 (kW) Remarks
Sector 1 US U33#21 3.3 72 11.00 2.59 3.25 158 5.4 Values for the SCU are for a max current of I = 450 A
DS SCU18#1 1.8 60 9.50 1.61 11.25 146 3.1
Sector 2 Canted US U33#7 3.3 71 13.27 2.05 4.55 121 3.2 400 µrad canting angle
DS U33#2 3.3 71 11.27 2.52 3.38 150 4.9
Sector 3 US APS27#7 2.7 88 11.00 1.65 7.3 149 3.3 Devices tuned in phase at 14.4 kev
DS U27#12 2.7 88 10.87 1.66 7.26 150 3.3
Sector 4 Canted US CPU 12.8 16 9.50 2.77:Lin
2.50:Cir
0.75:Lin
0.50:Cir
12:Lin
0.2:Cir
0.5:Lin
0.8:Cir
400 µrad canting angle. Entries for linear mode are for both horizontal and vertical fields. APS35#1 magnet material is SmCo.
DS APS35#1 3.5 67 9.75 2.99 2.44 165 6.6
Sector 5 US - - - - - - - -  
DS U33#29 3.3 72 11.00 2.63 3.16 161 5.6
Sector 6 US U33#25C 3.3 70 11.00 2.59 3.24 154 5.2 Values for the SCU are for a max current of I = 450 A
DS SCU18#2 1.8 60 9.50 1.61 11.25 146 3.1
Sector 7 US U33#1 3.3 72 11.00 2.63 3.17 160 5.5 Values for the HSCU are for a max current of I = 450 A. Gap is the coil winding diameter.
DS HSCU3155 3.15 38 31.0 1.21 5.98 18 1.33
Sector 8 US U33#27 3.3 72 16.00 1.57 6.34 93 1.9 Devices tuned to be in phase at 7.4 keV.
DS U33#33 3.3 72 16.00 1.58 6.26 94 2.0
Sector 9 US U33#32 3.3 72 16.25 1.53 6.50 91 1.8  
DS U33#10 3.3 72 13.00 2.13 4.32 128 3.6
Sector 10 US - - - - - - - -  
DS U33#5 3.3 72 13.20 2.07 4.49 125 3.4
Sector 11 US U33#15 3.3 72 13.00 2.10 4.39 127 3.5  
DS APS23#2 2.3 103 10.60 1.18 11.96 143 2.3
Sector 12 Canted US APS30#5S 3.0 69 11.00 2.05 5.00 132 3.6 1 mrad canting angle
DS APS27#5S 2.7 77 11.00 1.65 7.29 130 2.9
Sector 13 Canted US APS36#1S 3.6 57 11.00 3.15 2.17 142 5.9 1 mrad canting angle
DS APS30#8S 3.0 69 11.00 2.09 4.87 135 3.7
Sector 14 US APS27#3 2.7 88 10.50 1.76 6.74 160 3.8 Devices tuned to be in phase at 12.0 keV
DS APS23#1 2.3 103 10.40 1.21 11.72 146 2.4
Sector 15 US - - - - - - - -  
DS U33#3 3.3 72 11.00 2.62 3.18 160 5.5
Sector 16 Canted US APS30#7S 3.0 69 10.80 2.13 4.74 138 3.9 1 mrad canting angle
DS U33#35S 3.3 62 11.00 2.63 3.16 139 4.8
Sector 17 US - - - - - - - -  
DS U33#9 3.3 72 11.00 2.59 3.24 158 5.3
Sector 18 US - - - - - - - -  
DS U33#16 3.3 72 11.50 2.47 3.49 150 4.8
Sector 19 US - - - - - - - -  
DS U33#19 3.3 72 11.80 2.44 3.64 146 4.6
Sector 20 US - - - - - - - -  
DS U33#4 3.3 72 11.00 2.62 3.18 160 5.5
Sector 21 Canted US U33#38S 3.3 62 11.50 2.52 3.38 132 4.4 1 mrad canting angle
DS APS30#4S 3.0 69 11.00 2.08 4.90 134 3.7
Sector 22 US - - - - - - - -  
DS U33#30 3.3 72 11.00 2.63 3.17 161 5.5
Sector 23 Canted US U33#42S 3.3 62 11.30 2.50 3.41 132 4.3 1 mrad canting angle
DS APS30#3S 3.0 69 11.00 2.09 4.87 135 3.7
Sector 24 Canted US U33#40S 3.3 62 11.00 2.66 3.12 140 4.9 1 mrad canting angle
DS U33#39S 3.3 62 11.00 2.65 3.12 140 4.9
Sector 25 Canted US APS33#31S 3.3 62 11.50 2.50 3.42 131 4.3 1 mrad canting angle
DS APS33#26S 3.3 62 11.50 2.51 3.40 132 4.3
Sector 26 US U33#22 3.3 72 16.00 1.57 6.32 93 1.9  
DS U33#17 3.3 72 16.00 1.57 6.30 94 1.9
Sector 27 US APS30#9 3.0 79 11.00 2.07 4.94 153 4.2 Devices tuned to be in phase at 11.215 keV
DS APS30#2 3.0 79 11.00 2.07 4.93 153 4.2
Sector 28 US U33#20 3.3 72 11.00 2.49 3.38 158 5.4  
DS U33#6 3.3 62 11.00 2.59 3.24 136 4.6
Sector 29   IEX125 5
Circular
Hor. Lin
Ver. Lin
12.5 38 10.50 Kx
2.732
0.000
3.863
Ky
2.732
5.385
0.000

0.440
0.240
0.440

0.73
52
35

1.65
3.30
1.63
Quasi-periodic electromagnetic undulator
Ix=34.4 A, Iy=20.7 A (Circular),
Iy=47.6 A (Hor. Linear),
Ix=50.3 A (Ver. Linear)
Sector 30 US APS172#1 1.72 137 10.60 0.53 23.76 96 0.8 Devices tuned to be in phase at 23.7 keV (D=53.0 mm).
DS APS172#2 1.72 137 10.60 0.52 23.80 95 0.8
Sector 31 US - - - - - - - -  
DS U33#36 3.3 72 11.50 2.47 3.47 151 4.9
Sector 32 US U33#11 3.3 72 11.00 2.57 3.28 156 5.2  
DS U18#14 1.8 131 11.00 0.41 23.84 61 0.4
Sector 33 US - - - - - - - -  
DS U33#18 3.3 72 11.00 2.61 3.20 160 5.5
Sector 34 Canted US APS30#6S 3.0 69 11.00 2.09 4.87 135 3.8 1 mrad canting angle
DS U33#34S 3.3 62 11.00 2.62 3.18 138 4.7
Sector 35 US - - - - - - - - DS A and DS B are the revolver positions.
DS A APS172#3 1.72 137 11.00 0.51 23.95 91 0.7
DS B APS27#6 2.7 88 11.00 1.64 7.36 148 3.2

*US is upstream position and DS is downstream position on insertion device vacuum chamber.

1Total number of periods is listed. Effective number of periods = N - 2 because end magnets are not of full strength.

2Currently set allowed minimum gap.

3Zero emittance calculated values for a beam energy of 7.0 GeV.

4Calculated for a beam current of 100 mA using peak magnetic fields (not shown).

5 Power and power density calculated from the measured magnetic fields.
Updated: July 21, 2021

Maintained by Nicholas Weir( [email protected] )