Booster Septum Magnets

Drawings

Tables

( 22104 - 700000 ) Operational Parameters*
Number 1
Minimum Septum Thickness 2.0 mm
Physical Length 0.9 m
Effective Length 0.8 m
Bending Angle 0.2718 rad
Peak Field at 450 MeV 0.51 T
Gap Height 30 mm

*data from H.B. 7/96-- to be updated by S.M.

( 22106 - 200000 ) Operational Parameters*
Number 1
Minimum Septum Thickness 2.0 mm
Physical Length 1.06 m
Effective Length 1.05 m
Bending Angle 32.76 mrad
Peak Field at 450 MeV 0.73 T
Maximum Field 0.8 T
Gap Height 20 mm
Gap Width 34 mm

*data from H.B. 7/96-- to be updated by S.M.

( 220107-700000 ) Operational Parameters*
Number  
Minumum Septum Thickness 30 mm
Physical Length 1.79 m
Effective Length 1.75 m
Bending Angle 73.53 mrad
Peak Field at 7 GeV 0.98 T
Maximum Field 1.1 T
Gap Height 30 mm
Gap Width 40 mm

*data from H.B. 7/97-- to be updated by S.M.